Evaluation of New, Non-cyanide and Simple Method for Blood Haemoglobin Estimation.

Show simple item record

dc.contributor.author Sirajul Muneera, M.Y.
dc.contributor.author Wickramaratne, K.A.C.
dc.date.accessioned 2025-01-21T06:19:18Z
dc.date.available 2025-01-21T06:19:18Z
dc.date.issued 2014
dc.identifier.citation Sirajul Muneera MY, Wickramaratne KAC (2014). Evaluation of new, non-cyanide and simple method for blood haemoglobin estimation. Annual Academic Sessions, Faculty of Medicine, University of Ruhuna. vol.2, number:1, page 56 en_US
dc.identifier.uri http://ir.lib.ruh.ac.lk/handle/iruor/18926
dc.description.abstract Introduction Haemoglobin estimation is an important test. The standard Haemoglobin (Hb) estimation method is Cyanmethaemoglobin (HiCN) method. The Drabkin reagent used in HiCN method contains cyanide compounds which is hazardous for both environment and laboratory personnel. Aim To assess accuracy of Hb estimation by using distilled water as the reagent compared to the HiCN method. Materials and Method Retained 95 EDTA blood samples received at the Haematology laboratory, Teaching Hospital, Karapitiya were included in this study. The Hb value of each sample was estimated by standard HiCN method and using the new method (performed by using distilled water as the reagent). In Drabkin method 10 20 minutes are needed to develop stable Hb pigment for the estimation thus readings are taken at 20 minutes. Using new method, Hb concentration of all the samples were estimated immediately and after 20 minutes. Correlation studies and paired t test were taken to statistical analysis. Result A good correlation was observed between the cyanmethaemoglobin method and the new method. Paired t test values of immediate absorbance and absorbance at 20 minutes of the new method showed no significant difference from values obtained by standard Cyanmethaemoglobin method (immediate absorbance - P =0.819, Absorbance at 20 minutes - P =0.941). Discussion and Conclusion This study shows statistical agreement of results generated by new method against the standard. The new method doesn't require any reagent or toxic chemicals. However appropriate test validation study is needed to verify the applicability of new method for routine testing before it is recommended. en_US
dc.language.iso en en_US
dc.publisher Faculty of Medicine, University of Ruhuna en_US
dc.title Evaluation of New, Non-cyanide and Simple Method for Blood Haemoglobin Estimation. en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account